JW Series Limit Switches



LEVER ARM OPERATED
JW - 12       1 NO 1 NC
JW - 18
      2 NO 2 NC
MICRO ADJUSTABLE LIMIT SWITCHES
  • MICRO TRIP TORQUE ADJUSTMENT
  • REST POSITION ADJUSTMENT
  • REVERSE ACTION SETTING ADJUSTMENT
  • RAPID SETTING ADJUSTMENTS OF ROTARY OPERATION LEVER THROUGH 360 AND SCHEME CHANGES WITHOUT DISMOUNTING
  • FOUR POSSIBLE MOUNTING POSITIONS
ROLLER PLUNGER OPERATED
JW - 32       1 N.O 1 N.C.
JW - 38       2 N.O. 2 N.C. AND
PUSH ROD PLUNGER OPERATED
JW - 42       
JW - 48  
     
MICRO METER ADJUSTMENT LIMIT SWITCHES

PLUNGER TYPE SWITCHES SHOULD BE USED WHERE A MICROMETER ADJUSTMENT OF THE PLUNGER IS REQUIRED. THESE SWITCHES ARE SUITABLE FOR USE ON MACHINES WHERE SHORT, CONTROLLED CAM MOVEMENTS ARE PRESENT. OPERATION MUST BE IN LINE WITH PLUNGER AXIS OR CAN BE PERPENDICULAR TO THE PLUNGER AXIS ON THE ROLLER PLUNGER TYPES.

Non Plug-in Small Precision Limit Switches are designed specifically for use on modern machine tools, to control starting, stopping or reversing of electrical motors including safety and signalling light, lifting gear, hoists, conveyors, etc.

The two pole limit switches are identical in appearance and size to the popular single pole version. Two pole limit switches are desirable in many installations and can reduce the number of limit switches and control relays used.

Protected against oil, cutting lubricants and fine dust penetration by using compressed rubber rings, special gaskets, pressure die cast zinc top and aluminium bottom cover.

All the parts are ant-corrosive material and paints.

Spring return, Snap action, Quick make and Quick break contacts.

Operational current and voltage
AC 15 rating Single pole
1 NO + 1 NC
Changeover contacts
Double pole
2 NO + 2 NC
Changeover contacts
110 V
240 V
440 V
600 V
4 A
2 A
1 A
0.8 A
3.0 A
1.5 A
0.8 A
0.6 A
DC 13 rating Single throw Double throw Single throw Double throw
115 V
230 V
600 V
2.0 A
0.5 A
0.1 A
0.5 A
0.2 A
0.02 A
1.0 A
0.3 A
0.1 A
0.2 A
0.1 A
-
WIRING DIAGRAMS

1 N.O.1 N.C. contacts are Single Pole, Double Throw one circuit normally open and one circuit normally closed. These circuits are electrically separate, but cannot be used on opposite polarities.

2 N.O. 2 N.C. contacts: Each pole is electrically separate from the other and can be used on opposite polarities. The contacts of each pole, double throw-these circuits are electrically separate, but cannot be used on opposite polarities.

APPROXIMATE DIMENSIONS NOT FOR CONSTRUCTION (Dimensions in mm.)

Operating Data for types JO1 and JO2

Capacity:

Flexible
Solid
Thermal rating
Operating temperature
Storage temperature
Transfer time
Bounce time
Repeat Accuracy
Mechanical Life
Tips
2 x 1.5 mm2 max.
1 x 2.5 mm2 max.
10A
- 200 to + 700 C
- 400 to + 700 C
5 to 6 ms.
5 ms.
± 1/100th
20 million operations
Nickel Silver Solid
  Type JO1 Type JO2
  Pretravel 1.5-1.9 1.5-1.9
  Full Stroke 2.6-3.2 2.6-3.2
  Differential 0.8-1.2 0.6-1.2
  Reset Overtravel 0.4-1.0 0.4-1.2
  Distance ‘B’ From top of   buttonto mounting surface at   trip point Pretravel
2.4-2.0 2.4-2.0
  Operating force 0.3-0.4 kg. 0.2-0.4 kg.
SNAP SWITCH DIMENSIONS
LEVER ARM OPERATED
APPROXIMATE DIMENSIONS NOT FOR CONSTRUCTION (Dimensions in mm)

Figure 1 and 2 JW-12, JW-18

A B C D E F G H I J K L M N O P Q R
Length of Arm
5 mm
Arm Length
Plus 5 mm
24 68 56 5 68 -
70
56 -
58
8 11 23 78 19 37 27 89 98 29

OPERATING TORQUE 3.16 Kg Cm Repeat Accuracy + 0.025 with 35 mm arm.

NOTE 1: For reverse operation place arm and roller in similar position to left of centre line and reverse position of return spring.

NOTE 2: If roller is used in dotted position (side view) it will not pass over cover, and unit must be mounted accordingly.

ROLLER PLUNGER & PUSH ROD PLUNGER OPERATED
APPROXIMATE DIMENSIONS NOT FOR CONSTRUCTION (Dimensions in mm)

Figures 1 & 2 types JW-32, JW-38, JW-42, JW-48

Type A B C D E F G H I J K L M N O P
JW-32, JW-38
JW-42, JW-48
24 56 5 46 5 28 6 10 3 19 78 37 27 89 98 8
Dimensions (mm)

TOP